mailtomail@emamidesign.de
phone+49 (0)30 479 87 654

IP Rating / Degree of Protection

HMI, Product Safety & Compliance

What does IP Rating / Degree of Protection mean?

Under IEC 60529, the IP rating describes the protection provided by an enclosure against access to hazardous parts, ingress of solid foreign objects, and harmful effects caused by the ingress of water. It makes defined enclosure-protection characteristics comparable and verifiable.

For Product Design, the IP rating is particularly relevant for electrical and electronic products. Seams, buttons, connectors, speaker openings, ventilation, seals, and mounting points become not only construction details but parts of a verifiable protection concept.

How is the IP Code structured?

The IP Code consists of the letters IP followed, in most cases, by two characteristic numerals. The first numeral describes protection against access to hazardous parts and solid foreign objects; the second describes protection against water. If one of these characteristics is not specified, an X may be used in its place.

Higher numerals represent more extensive defined protection requirements within their respective category, but they should not be understood as a general scale of quality or robustness. What matters is the specific protective effect that was tested and the condition or product configuration in which the rating applies.

Which IP ratings are frequently relevant in practice?

IP20 – Protection against solid foreign objects 12.5 mm and larger and against access with a finger; no protection against water.
IP4X – Protection against solid foreign objects 1 mm and larger; water protection is not specified.
IP45 – Protection against solid foreign objects 1 mm and larger and against water jets.
IP65 – Dust-tight and protected against water jets.
IP67 – Dust-tight and protected against the effects of temporary immersion.
IP68 – Dust-tight and suitable for continuous immersion under specified, product-specific conditions.
IP69 – Dust-tight and protected against high-pressure/high-temperature water jets.

These short descriptions provide a quick practical orientation and do not replace the specific test conditions defined in IEC 60529. A high IP rating therefore does not automatically mean “waterproof” or generally “more robust”: the decisive factors are the specific exposure tested, the intended mounting condition, and – particularly for IP68 – the defined test parameters.

What does an IP rating not cover?

IEC 60529 does not automatically assess mechanical impact resistance, corrosion, UV resistance, chemical resistance, drop resistance, or general weather resistance. Mechanical impacts on enclosures are classified separately by the IK Code.

Long-term sealing performance through ageing, wear, repeated opening, or manufacturing variation is also not determined by the IP number alone. Depending on the product, additional lifetime, climate, material, or product-specific tests may be necessary to ensure that the required protection is maintained in real use.

Which design decisions influence the IP rating?

Parting seams, seal geometry, seal compression, screw spacing, wall stiffness, tolerances, drainage, pressure equalization, and the integration of controls or interfaces all directly affect sealing performance. At the same time, seals and overlaps influence proportions, seam appearance, assembly, and service access. The objective is a clear product architecture, reproducible assembly, and verifiable geometry. The fundamental classification is defined in IEC 60529:1989+A1:1999+A2:2013.

Sources: IEC 60529:1989+A1:1999+A2:2013, Degrees of protection provided by enclosures (IP Code) – https://webstore.iec.ch/en/publication/2452 · IEC, Ingress Protection (IP) ratings – https://www.iec.ch/ip-ratings

Related terms

Related EMAMIDESIGN topics